• establish a serial console connection between the computer and the VMP; describe the file structure of the data logger
  • run the ‘calibrate all’ function and interpret the results
  • set up RSILink for data file transfer
  • transfer files to and from the data logger using a USB connection; interpret and edit a configuration file (setup.cfg)
  • differentiate between the [root], [matrix], [vehicle_info] *new, and [channel] sections of the configuration file
  • identify which calibration para-meters are board-specific and which ones are probe-specific
  • describe the data file format
  • interpret the log file